Clock Configuration Alarm

acClockConfigurationAlarm

Alarm

acClockConfigurationAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.149

Description

The alarm is sent when multiple source clock synchronization methods are enabled (NTP, SIP Date header, and/or PTP) for the device. In this scenario, the device uses the clock synchronization method in this order of priority: NTP, then SIP Date header, and then PTP. For example, if you enable both NTP and SIP Date header, the device uses NTP (ignoring SIP Date header settings). If you enable both SIP Date header and PTP, the device uses SIP Date header (ignoring PTP settings).

Note: PTP is applicable only to Mediant VE/CE SBCs deployed on Azure or Hyper-V.

Default Severity

Minor

Source Varbind Text

Board#1

Event Type

operationalViolation

Probable Cause

configurationOrCustomizationError

Alarm Text

Board Configuration Error: DateHeaderTimeSync would be ignored as NTP is enabled.

Severity

Condition

Text

Corrective Action

Minor

Clock synchronization by NTP and SIP Date header are enabled.

"Clock Synchronization from SIP Date header ignored as NTP is enabled"

Disable one of the clock synchronization methods.

Minor

Clock synchronization by PTP and NTP are enabled.

"Clock Synchronization from PTP ignored as NTP is enabled."

Disable one of the clock synchronization methods.

Minor

Clock synchronization by SIP Date header, PTP, and NTP are enabled.

"Clock Synchronization from SIP Date header and PTP ignored as NTP is enabled."

Disable two of the clock synchronization methods.

Minor

Clock synchronization by SIP Date header and NTP are enabled.

"Clock Synchronization from SIP Date header ignored as NTP is enabled."

Disable one of the clock synchronization methods.

Minor

Clock synchronization by SIP Date header and PTP are enabled.

"Clock Synchronization from PTP ignored as SIP is enabled."

Disable one of the clock synchronization methods.

Cleared

Only one clock synchronization method is enabled.

-

-